Complete unit
Review the existing duty, available footprint and connection drawing to select a complete HEXCBLOC unit.
Compare Alfa Laval Compabloc CP120 and PANSTAR HEXCBLOC 120: dimensions, design limits and complete-unit or core replacement.
| Parameter | ALFA LAVAL Compabloc CP120 | PANSTAR HEXCBLOC 120 |
|---|---|---|
| Maximum width | 2,190 mm | 2,190 mm |
| Maximum height | 3,500 mm | 3,500 mm |
| Published design pressure | ASME maximum: 42 bar | Standard: full vacuum to 32 bar |
| Published temperature range | −46 °C → 343 °C | −40 °C → 300 °C |
| Construction | Welded plate pack; removable panels | Welded plate pack; removable panels |
| Core / plate pack | Compabloc CP120 | Replacement core available following drawing and configuration review |
Published range values are selection references. Plate count, material, nozzle position, baffles and the approved drawing determine the supplied configuration. Similar dimensions do not establish identical operating limits or a direct fit.
Review the existing duty, available footprint and connection drawing to select a complete HEXCBLOC unit.
For core replacement, supply the serial plate, plate pattern, plate count, material and core drawing. Confirm panel seals, frame interfaces and baffle arrangement.
Alfa Laval Compabloc · 200000002-1-EN-GB · HEXCBLOC 120 · Published specifications
Alfa Laval and Compabloc identify the original equipment. HEXCBLOC is supplied by PANSTAR.
Provide both fluids, flow rates, inlet and outlet temperatures, operating and design pressures, allowable pressure drop and material requirements. For a replacement, include the nameplate and arrangement drawing.